AND LCCU21N200 Manual - Página 2
Procurar online ou descarregar pdf Manual para Instrumentos de medição AND LCCU21N200. AND LCCU21N200 2 páginas. Usb button cell for force measurement
USB BUTTON CELL FOR FORCE MEASUREMENT
LCCU21 Series
LCCU21N100 LCCU21N200 LCCU21N500 LCCU21KN001
3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo
170-0013 JAPAN
Tel: [81](3)5391-6132 Fax: [81](3)5391-6148
1. OUTLINE
Check the following packing contents before use.
- Main unit (load cell, cable and plastic case) ............................... 1
- Mounting holder
APX-4036220: For LCCU21N100 or LCCU21N200
APX-4036221: For LCCU21N500 or LCCU21KN001
- USB cable ................................................................................. 1
- Instruction manual (this sheet) .................................................................. 1
Plastic case
Load cell
Main unit
Mounting holder USB cable
2. INTRODUCTION
The LCCU21 series is a compact and light compression digital load cell
for force measurement. These can be used for the load distribution
measurement, compression measurement and etc. Also, connecting
the load cell to a computer using the USB cable allows for easy
measurement.
3. SOFTWARE FOR MEASUREMENT
By using the "WinCT-DLC" software for measurement, the measurement data can
easily be confirmed on a computer.
"WinCT-DLC" can be downloaded from A&D's website (https://www.aandd.jp).
4. SPECIFICATIONS
Model No.
LCCU21N100 LCCU21N200 LCCU21N500 LCCU21KN001
100 N
200 N
500 N
Rated capacities
(10.20 kg)
(20.39 kg)
(50.99 kg)
100.00
200.00
500.00
Rated output
0.50 (0.5%)
1.00 (0.5%)
2.50 (0.5%)
Combined error
0.5 % of R.O.
Supply voltage
DC 5 V (USB bus power)
Power
Average current
Less than 50 mA
consumption
*1
Zero balance
±2 % of R.O.
Temperature effect on zero
0.6% of R.O. / 10°C
Temperature effect on span
0.6% of LOAD / 10°C
Compensated temperature
0 °C to 70 °C
range
Permissible temperature
-10 °C to 80 °C
range
Maximum safe overload
150 % of R.C.
A/D conversion rate
100 times / s
Select from None, 0.7, 1.0, 1.4, 2.0, 2.8, 4.0, 5.6, 8.0,
Digital filter
11.0 Hz (default value: 1.0 Hz)
Resonance frequency
45 kHz
55 kHz
30 kHz
*1, *2
From load cell to case: 2 mm, 2 m length
Cables
USB cable (accessory): 4 mm, 1.5 m length
Dustproof / waterproof
*2
IP64 compliant
Weight
Approx. 50 g
Approx. 55 g
*3
Communications standard
Conformant to USB Ver. 2.0 Full Speed
USB connector
micro-B type
Baud rate
38400 bps
Character bit length
8 bit
Parity
Even
Communication
settings
Stop bit length
1 bit
Terminator
CR LF
Code
ASCII
*1: Reference value *2: Load cell only *3: Main unit (load cell, cable, plastic case)
1WMPD4003374C
5. INSTALLATION
5.1. ATTACHING THE LOAD CELL
Attach the load cell to a rigid and flat base (the fixed surface). If there
is slope or distortion on a part of the base, it affects the measurement
accuracy.
The mounting surface is gray area on the bottom of the load cell in the
figure.
Do not apply load to the concavity of the center of the bottom ( mesh
area).
Don't defile with adhesive on mesh area.
.... 1
Mesh area : Don't
apply load and
don't defile with
adhesive.
Gray area :
Mounting surface
Clean the mounting surface before attaching the load cell.
Fix the position of the load cell using adhesive or the mounting holder.
Adhesive used
Use the cyanoacrylate adhesive.
Push gently the load cell so as to keep the position. Paste the
adhesive to the place contacting the fixed surface and outer
circumference of the load cell. Hold the load cell until maintaining
the position. Do not apply excessive load and don't defile with
adhesive on mesh area.
Peel and shave adhesive using cutter and etc. when removing the
load cell. Don't hit and shock to the load cell when removing it. Note
injury and damage of the load cell in removing it.
Example of the load cell installation
Adhesive used
Paste the adhesive to the place
contacting the fixed surface and
outer circumference of the load cell.
1 kN
(102.0 kg)
1000.0
5.0 (0.5%)
Mounting holder used
Put the load cell into the mounting holder. Fix them.
Note M3 bolts are not included in accessories.
Example of the load cell installation
Mounting holder used
M3 bolts (2 pieces)
Mounting holder
Load cell
Mounting holder
35 kHz
When using the load cell by securing the plastic case, secure it as
shown in the figure below using the two installation holes.
Note M3 bolts are not included in accessories.
M3 bolts (2 pieces)
Use the load cell with the load cell and computer at the same potential.
Charging with the load cell may cause malfunctions.
Specifically, take measures such as grounding the load cell.
Grounding example
Mounting holder
Outlet with grounding
terminal
Grounding
line
5.2. LOADING TO THE LOAD CELL
Load a vertical load to the load cell indicated in the figure below. Avoid
eccentric load, horizontal force and moment.
Direction of force
Apply load to the load cell through a rigid surface.
5.3. CAUTIONS
Avoid a shock and excessive force to the load cell.
Keep a constant temperature using insulation, when the load cell is
installed in a place exposed to direct sunlight or radiant heat.
Handle the load cell cable gently. Do not pull it when using the load cell.
Prevent the plastic case from getting wet.
Only the provided USB cable should be used with this load cell. Using a
USB cable other than the provided USB cable may prevent the load cell
from making proper measurement due to the effect of noise.
6. COMPUTER CONNECTION PROCEDURE
1) Connect the device to the computer using the provided USB cable.
2) Select the device manager on the computer.
3) Click the "Ports (COM & LPT)".
4) Confirm the COM Port number displayed. The numerical value indicated
by x in "USB Serial Port (COM x)" indicates the COM Port number.
If multiple load cells are simultaneously connected to the computer
without confirming the COM Port number, COM Port identification
becomes difficult. Confirm the COM Port number one by one beforehand
*
when connecting.
4
5) Select the "Port Settings" tab in the "USB Serial Port (COM x) Properties",
then select "Advanced".
6) In the "BM options", set the "Latency Timer (msec)" under 10 (reccomended
value is 3). If it is not to set, a communication delay may result.
*
4 If the COM Port number cannot be displayed due to failure in installing
the driver, refer to the website of Future Technology Devices
International. Ltd. to install the driver.
7. COMMAND LIST
In this document, only typical commands are discribed. To reference other
commands and details of those commands, download the "LCCU21 WEB
INSTRUCTION MANUAL" from A&D's website.
Host side
Items
transmission
LCCU21 side response command
command
RFMVXXXXXXXX<CR><LF>
Floating point type
RFMV<CR><LF>
XXXXXXXXX is the floating point type
measurement value reading
measurement value
Floating point type
RCFMXXXXXXXX<CR><LF>
measurement value
RCFM<CR><LF>
XXXXXXXXX is the floating point type
sequential reading
measurement value
US,XXXXXXXXX
N<CR><LF>
Fixed point type
RLMV<CR><LF>
XXXXXXXXX is the fixed point type
measurement value reading
measurement value
Host side
Items
transmission
LCCU21 side response command
command
Fixed point type
US,XXXXXXXXX
measurement value
RCLM<CR><LF>
XXXXXXXXX is the fixed point type
sequential reading
measurement value.
Stop sequential
STOP<CR><LF>
STOP<CR><LF>
reading
Response when command error occurs
Items
LCCU21 side response command
Format error
? <CR><LF>
Setting value error
V<CR><LF>
8. LED DISPLAY
Orange
TX (sending),
Yellow
Blue
Power (power supply)
9. MAINTENANCE
Remove all dirt and dust from the load cell, and always use it in
a clean environment.
When cleaning, use an air blower.
10. DIMENSION
(Number) : Reference value.
(B)
Load cell
82
2, length: 2m
(93)
j
is a space (0x20)
N<CR><LF>
is a space (0x20)
RX (receiving),
Plastic case
G
2- 3.5
H
Thickness=1.5
2- 3.5
Stainless steel
USB connector slot
Unit: mm