Aleo ELEGANTE Manual de instalação - Página 9
Procurar online ou descarregar pdf Manual de instalação para Painel solar Aleo ELEGANTE. Aleo ELEGANTE 14 páginas. Bipv modules
Também para Aleo ELEGANTE: Manual de instalação (16 páginas)
8 Electrical installation
8.1
Personal protection
WARNING
High DC voltages during storage, installation,
operation and maintenance. Risk of fatal
electric shock!
aleo modules may only be installed by qualified
technicians with a high level of expertise (see
sample of cennection
Never touch the electrical connections of a solar
module under any circumstances, not even if
you have disconnected the photovoltaic
generator.
WARNING
Electric arcs are generated when electrical
components are connected or disconnected
incorrectly.
Before you carry out any work on electrical
components, disconnect the photovoltaic
generator.
Figure 8B
WARNING
Contact with live parts due to defective
insulation or damaged / fallen off
junction box covers.
Do not touch damaged parts with your bare
hands.
Use protective clothing and suitable, insulated
tools.
8.2 Electrical Connections
For modules connected in series, only modu-
les of the same amperage rating may be
used together. For modules connected in par-
allel, modules with the same voltage
ranges must be used together. The modules
must not be operated at a higher voltage
than the permissible system voltage.
aleo solar GmbH | Marius-Eriksen-Straße 1 | 17291 Prenzlau | Germany | [email protected]
Figure 8A
).
Figure 8C
Installation Manual GG Elegante Rel. 1.2, 06/2019, EN
Copyright © 2019 aleo solar GmbH
8A
8B
8C
9