Appendix C - Specifications
Analog Audio Inputs
Input Impedance
Input Sensitivity
Gain
Polarity
Speaker Output
Mode / Process
Power Output - 8 ohms
Per Channel
20 Hz-20 kHz, < 0.02% THD
1 kHz, 0.02% THD, (Watts)
1 kHz, 1% THD
CEA 2006 1 kHz Burst Power
Power Output - 4 ohms
Per Channel
20 Hz-20 kHz, < 0.02% THD
1 kHz, 0.02% THD, (Watts)
1 kHz, 1% THD
CEA 2006 1 kHz Burst Power
Distortion
THD + N, 20 Hz - 20 kHz
THD + N @ 1 kHz, 1W
Intermodulation Distortion
(SMPTE or Twin-tone)
Frequency Response
Damping Factor - 8Ω load
Damping Factor - 4Ω load
Signal to Noise Ratio
Slew Rate
Crosstalk
Trigger Input
Dimensions (W x H x D)
AT522, AT523. AT524, AT542
AT525 - AT528, AT543, AT544
Weight
AT500NC Manual
-
(Specifications subject to change without notice)
One Single-ended (RCA) jack per channel & One Balanced (XLR) jack per channel
20 kΩ Balanced for each phase
AT52Xnc - 1.5V input for 200W RMS
8 ohms
Balanced; Pin-2 = Positive, Pin-3 = Negative for Non-Inverting Output
Binding posts; 1 pair per channel
Standby: Amplifier is ready to be turned on via front panel switch or remote trigger.
Overcurrent, D.C., and/or thermal protection: Amplifier will cycle.
Catastrophic D.C. or output stage failure: Amplifier will shut down.
AT52X
NC
8 Channels
2 Channels
200W
200W
210W
300W
AT52X
NC
4 Channels
2 Channels
300W
350W
375W
450W
AT52Xnc
0.02%
0.005%
Less than 0.03%
+0, -.5 dB, 5 Hz to 20 kHz, load independent
AT52Xnc
>4000 at 100 Hz; >1600 up to 20 kHz
>2000 at 100Hz; >800 up to 20 kHz
123 dB referenced to rated output (A-Weighted)
17" x 5 11/16" x 10 5/8" (432 mm x 145 mm x 270 mm)
17" x 5 7/8" x 15 1/2" (432 mm x 150 mm x 394 mm)
Add 1 inch (25mm) depth for connectors.
Model dependent: 39 lbs. to 65 ½ lbs.; 17.8 to 29.8 kg
11
Toggle Switch to choose jack
AT54Xnc - 2.35V RMS input for 500W
28.5dB
(Single-Ended) Non-Inverting
2 Channels
200W
500W
225W
550W
250W
600W
300W
700W
2 Channels
300W
500W
350W
550W
400W
600W
500W
700W
>2000 at 100Hz; >800 up to 20 kHz
>1000 at 100Hz; >400 up to 20 kHz
>60V per microsecond
>90dB
3-24 VDC; Steady State
8 ohms
AT54X
NC
1 Channel
600W
650W
700W
800W
AT54X
NC
1 Channel
900W
950W
1000W
1000W
AT54Xnc
0.02%
0.005%
Less than 0.03%
AT54Xnc
Rev-05/18