Milk Meter Fault Finding Scheme

Data Communication Faults

Symptom
No Data Communication/No Cow Number
Displayed On LCD
13 | Milk Meter Service Manual | v1.2
Possible Cause
Control address setting incorrect
Micro M3S setting incorrect
Micro M5 setting incorrect
Wiring connection fault
Solution
Check control address setting.
Check subroutine 311 and 312.
Check settings
Check all data cable connections in connections box
and Micro M3S or Micro M5.
Check connections in control lid.
Check connections in connections box.
Check all data cable connections in connections box
'daisy-chain'- into and out of all connection boxes.
Check for duplicate control address settings.