CARNES HXHAF Manual do proprietário e manual de referência - Página 10

Procurar online ou descarregar pdf Manual do proprietário e manual de referência para Humedecer CARNES HXHAF. CARNES HXHAF 20 páginas.

CARNES HXHAF Manual do proprietário e manual de referência
Installation

Wiring

**TURN POWER OFF TO ALL HVAC EQUIPMENT BEFORE WIRING**

Power Connection Wiring (R, C)

The humidistat controller is powered from the R and C connections
from the furnace and needs continuous power to operate properly.
Proper R and C wiring is shown in Figure 5.

Outdoor Temperature Sensor Wiring (ODT)

The outdoor temperature sensor wires will connect into the ODT
terminals on the humidistat terminal block as shown in Figure 5.

Heat Signal Wiring (W)

The W terminal is the heat signal from the thermostat. Wire the W
terminal from the furnace control panel to the W terminal on the
humidistat terminal block as shown in Figure 5.

Automatic External Fan Control Wiring (G, GF)

Fan control wiring should be completed when possible. If the fan
control wiring is not possible then the humidistat should only be ran in
Heat-Only Mode as described in the Operation section of this
document.
The wire running from the G terminal on the furnace control board to
the G terminal on the thermostat will need to be disconnected. The G
terminal from the thermostat will then need to be wired directly to the
G terminal on the humidistat terminal block. The G terminal on the
furnace control panel will then need to be wired directly to the GF
terminal on the humidistat terminal block. See Figure 5.
Humidifier Control Wiring (H1+, H2-)
The humidifier control terminals are labeled on the humidistat as H1+
and H2-. These terminals will need to be wired directly to the humidifier
as shown in Figure 5. H1+ on the humidistat terminal connects to the
HUM terminal on the humidifier control panel and H2- on the humidistat
terminal connects to the GND terminal on the humidifier control
panel.
10
|
RESIDENTIAL HUMIDISTAT
Form 16763