Operation
Figure 10: Mode Selection Screen
Modes of Operation
General Function
The residential humidistat will run the humidifier when the duct/room humid-
ity level is below the humidity setpoint and any one of the following is true:
•
Heat signal from thermostat is on
•
Fan signal from thermostat is on
•
Fan signal from humidistat is on
When the humidistat receives an on signal it will control the humidifier to
maintain the desired humidity level by ON/OFF or modulating control. ON/
OFF control turns the humidifier on when the humidity level drops 10% below
setpoint and turns the humidifier off 10% above setpoint. Modulating control
sends a 010 VDC signal to the humidifier to proportionally control the steam
output of the humidifier.
When the humidifier output changes from ON to OFF, the humidistat
will keep the fan running for 90 seconds to prevent excess steam from
condensing in the duct.
There are four selectable modes the humidistat can operate in to provide the best
humidity control for any household. These modes can be selected in the humid-
istat MODE SELECTION screen (Figure 10) and determine how the humidistat
reacts to the fan and heat signals.
16
|
RESIDENTIAL HUMIDISTAT
Form 16763