3.4 TROUBLESHOOTING
3.4 TROUBLESHOOTING
3.4 TROUBLESHOOTING
3.4 TROUBLESHOOTING
3.4 TROUBLESHOOTING
As with any current loop, power supply and loop continuity are both imperative. If a problem
occurs, a methodical approach, beginning at the power supply is best.
3.4.1 Troubleshooting Steps
1. Measure power supply voltage across "loop+" and "loop-" terminals. Meter will read
between 12 and 40 VDC. (meter set to DC volts)
2. Disconnect one wire (+) from the signal receiver and install an accurate milliamp
meter in series with the receiver. The signal should correspond proportionally to the
height of liquid in the tank. (meter set to DC mA)
NOTE:
Above may differ if signal scaling is being done via microprocessor based
receiver. Product specific gravity values must be used in calculation.
3. If step 1 and 2 are satisfactory , the problem is with the receiver. (If supplied by
Anderson, refer to the instruction manual for that instrument).
4. Check all wiring connections between loop components. If OK, proceed to step 5.
5. With loop disconnected, the next step is to determine if there is a short to the
housing. This is accomplished by placing the (+) lead of the ohm meter on the loop+
terminal, and the (-) lead to the housing. The process should then be reversed. In
both cases, the meter should register infinite resistance. The process should then
be repeated on the loop- terminal of the sensor. Again, the meter should register
infinite resistance. If test is OK, proceed to step 6,
6. Wire transmitter independently of loop using two 9 volt batteries for power and
milliamp meter as a receiver. If signal is proper, approximately 4 mA with no product
on sensor, then problem is with external wiring.
NOTE:
Be sure to observe proper polarity as described in Figure 2-3
If any of the above indicate a transmitter problem, call your local distributor, or Anderson
Technical Service directly.
P
17
AGE