ANDERSON-NEGELE NSL-F series Manual de instruções - Página 18

Procurar online ou descarregar pdf Manual de instruções para Acessórios ANDERSON-NEGELE NSL-F series. ANDERSON-NEGELE NSL-F series 20 páginas. Continuous level sensor. sensors for food and biopharma.
Também para ANDERSON-NEGELE NSL-F series: Manual de instruções (20 páginas)

NSL-F Series Operating Manual
Resolution
Accuracy
Linearity
Reproducibility
Temperature drift
Response time t90
Electrical connection
Weight
Rod length >500 mm
Rod length <500 mm
Media with conductivity
>50 µS/cm (beer, milk)
Media with conductivity
<50 µS/cm
Rod length >500 mm
Rod length <500 mm
At 25 °C
Supply voltage
Protection class
Output signal
Ohmic resistance
<0.1% of rod length
<0.5 mm
<1% of rod length
Depending on temperature, tank contour,
medium, distance to tank wall
<1.0% of rod length
<0.2% of rod length
<1.0 mm
≤0.1%
<100 ms
18...36 V DC
IP 69K
4...20 mA, galvanically isolated -> housing
0... 750 Ω
920 g at length of 1.5 m
18