Commander P2 Autopilot Operation — Quick Reference Guide
WORK
mode
A
N
(
or
is shown in upper left of display)
W
W
Caution! WORK mode should only be used by experienced
operators who fully understand the operation of this mode.
WORK mode is engaged automatically at a set speed
(see Work Trip Point in the Operation Manual),
if the mode is activated by the vessel's operator.
WORK mode can also be engaged manually (see Manual).
Note: WORK mode is not available if Vessel Type
in the DOCKSIDE menu is set to SAIL.
To activate WORK mode:
1. Switch to AUTO mode or NAV mode.
2. Press
for 3 seconds.
Fn
To de-activate WORK mode:
1. Press
for 3 seconds.
Fn
AUTO or NAV WIND
A
N
(
or
is shown in upper left of display)
W
W
Be sure to read the relevant sections of the Operation
Manual prior to using a WIND mode.
Note: WIND modes are available only when Vessel Type
in the DOCKSIDE menu is set to SAIL (a compatible wind speed
transducer must also be connected to the autopilot).
To enter AUTO or NAV WIND mode:
1. Bring the vessel around so that the wind angle on the bow
is between about 45° and 165° (Port or Starboard)
2. Switch to AUTO or NAV mode
3. Press
for 3 seconds
Fn
While in a WIND mode:
Use
to change angle to wind. Range is limited to
between CLOSE HAUL and GYBE HOLD POINT settings.
Use
and
or
Press
to switch to the alternative AUTO WIND mode
AUTO
(press it again to switch back to regular AUTO WIND mode).
To exit AUTO or NAV WIND mode:
1. Press
for 3 seconds.
Fn
modes
to TACK or GYBE.
DOCKSIDE
Refer to Installation Manual when using this menu
To enter the DOCKSIDE menu:
1. Begin with Power OFF.
2. Press
3. Release all buttons once the VERSION numbers
Use
Use
Press
Reset [do not use unless advised by ComNav]
Vessel Type [sets initial steering parameters]
Analog Compass Type [choose appropriate one]
Compass Setup [sets up Compass]
Drive Setup [sets up rudder limits, etc.]
Exit
Alarm Output [sets External Alarm type]
Thruster Type [choose appropriate one]
Thruster Minimum [% of max. supply voltage]
Thruster Maximum [% of max. supply voltage]
(Thruster operation requires a CT7 Interface)
Language [choose appropriate one]
To exit the DOCKSIDE menu:
Highlight Exit and press
or else press
(all settings are automatically saved on exiting)
This sheet contains summary information on how to set up and
operate the Commander P2 autopilot.
This information should not be considered as a complete
guide to setting up and operating the autopilot.
Be sure to read and understand the important safety and
operational information presented in the Commander P2
Installation & Operation Manual before using the autopilot.
#15 –13511 Crestwood Place
Richmond, British Columbia
Canada. V6V-2G1
Tel. 604 207 1600 Fax: 604 207 8008
Internet: www.comnav.com
E-mail: [email protected]
Document PN 29030033 V1.2
menu
while holding both
are displayed.
or
to select & highlight a parameter.
to change value of selected parameter.
to begin automated Setup Scripts:
Fn
(go to STANDBY mode)
Fn
until RELEASE appears in display.
and
Fn