INSTALLATION AND OPERATION MANUAL
Multiple Port Configuration Window
The Multiple "Port Configuration" window enables to apply same configuration to multiple ports in a single screen.
This is the fastest way to apply similar changes to multiple ports.
User Input
Disable
Check this box to disable selected ports. Check boxes "Disable", "Enable" & "Force Power"
are mutually exclusive.
Enable
Checking this box will enable selected ports.
Force Power
Check this box to force selected the port to "Power On". This will bypass detection,
classification and power management steps and no violation will be honored.
Reset Statistics
Check the box to reset port statistics.
Detection Type
Choose the detection type to be used for selected ports:
» "None" for bypassing detection
» "2-point" for 2-point detection
» "4-point" for 4-point detection
» "4-point+legacy" for 4-point followed by legacy
» "2-point+legacy" for 2-point followed by legacy
» "Legacy" for legacy detection only
» This option will be considered when next time detection is performed on those ports. This
Tech SupporT: 1.888.678.9427
Figure 9: Multiple Port Configuration Window
will not affect ports in delivering state. To perform detection on a port perform disable and
enable the port again.
CLFE(X)IPS
INS_CLFE(X)IPS_REV–
12/15/11
PAGE 10