INSTALLATION AND OPERATION MANUAL
FIGURE 12 – TYPICAL APPLICATIONS (CONT'D)
RS422 Bus With Standard Fiber Units
Any ComNet fiber unit w/
24 Contacts IN
24 Contacts OUT
From Address 1 – Right
24 Contacts IN
24 Contacts OUT
From Address 2 – Right
24 Contacts IN
24 Contacts OUT
From Address 3 – Right
Multiple Units With The Same Address
24 Contacts IN
24 Contacts OUT
From Address 1 – Right
24 Contacts IN
24 Contacts OUT
From Address 1 – Right
Contact inputs on the left side will be logic OR'ed together as both units have the same address. (e.g. closing input 1 on either unit will cause relay output 1 to close on the unit(s) with
address 1 on the right side of the system.)
In addition, the relay outputs on both units on the left side will close when the corresponding input is closed on the unit(s) with address 1 on the right side of the system.
TECH SUPPORT: 1.888.678.9427
LEFT
FVT10D2I1C4E
an RS422 data channel
FDC24NL
B
Address 1
A
FDC24NL
B
Address 2
A
FDC24NL
B
Address 3
LEFT
FDC24NLSFP
Address 1
A
FDC24NL
B
Address 1
FDC24NL[SFP] SERIES
RIGHT
FVR10D2I1C4E
Any ComNet fiber unit w/
an RS422 data channel
FDC24NL
B
Address 1
A
FDC24NL
B
Address 2
A
FDC24NL
B
Address 3
RIGHT
FDC24NLSFP
Address 1
Cat5 Straight Patch Cable
Fiber Optic Cable
24 Contacts IN
24 Contacts OUT
From Address 1 – Left
24 Contacts IN
24 Contacts OUT
From Address 2 – Left
24 Contacts IN
24 Contacts OUT
From Address 3 – Left
24 Contacts IN
24 Contacts OUT
From Address 1 – Left
INS_FDC24NL[SFP]_REV–
12/29/11
PAGE 8