9.3 Other technical data
TOTAL POW‐
ER:
Electric sup‐
ply:
Appliance cat‐
egory:
Gas connec‐
tion:
Appliance
class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Rapid
Semi-rapid
Auxiliary
WARNING!
This appliance does not
function with the existing gas
settings if installed in Malta.
Therefore, before connecting
the appliance it is essential
to change the nozzles
according to the type of gas
used according to the table
below.
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
Rapid
Semi-rapid
Auxiliary
Gas original: G20 (2H) 20 mbar
Gas replace‐
G30 (3+) 28-30 mbar
ment:
G31 (3+) 37 mbar
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car‐
tridge fuse
II2H3+
R 1/2"
3
NORMAL POWER
kW
3,0
2,0
1,0
NORMAL
MINIMUM
POWER
POWER
kW
kW
2,8
0,75
2,0
0,45
1,0
0,33
MINIMUM POWER
kW
0,75
0,45
0,33
INJECTOR
NOMINAL GAS FLOW g/h
MARK
G30 28-30
mbar
86
204
71
145
50
73
8 kW
567 g/h
557 g/h
INJECTOR MARK
119
96
70
G31 37 mbar
200
143
71