9.2 Bypass diameters
BURNER
Multi Crown
Rapid
Semi-rapid
Auxiliary
9.3 Other technical data
Gas original:
TOTAL POW‐
Gas replace‐
ER:
ment:
Electric supply:
220-240 V ~ 50/60 Hz
Appliance cate‐
II2H3+
gory:
Gas connec‐
G 1/2"
tion:
Appliance
3
class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Rapid
Semi-rapid
Auxiliary
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
Multi Crown 3,65
Rapid
2,8
Semi-rapid
2,0
Auxiliary
1,0
G20 (2H) 20 mbar
G30 (3+) 28-30 mbar
G31 (3+) 37 mbar
NORMAL POWER
kW
4,0
2,95
1,85
1,0
MINIMUM
POWER
kW
1,4
0,95
0,6
0,33
Ø BYPASS 1/100 mm
57
52
35
28
MINIMUM POWER
kW
1,4
0,75
0,6
0,33
INJECTOR
NOMINAL GAS FLOW g/h
MARK
G30 28-30
mbar
095
265
86
204
71
145
50
73
ENGLISH
11,65 kW
832 g/h
818 g/h
INJECTOR MARK
146
119°
92
70
G31 37 mbar
261
200
143
71
17