Level Sensor Assembly (F and S style)
FLOAT Installation: Install the float with retaining fastener ("e-clip") for the "F" style probe and install the float with retaining
fastener ("R-clip") for the "S" style probe as shown.
"F" style probe with ("e-clip")
Sensor Installation – Tri-Clamp Flange style
NOTE: The Rigid Level sensor in this style requires a
minimum tank bottom clearance of 3/8". Tank bottom
clearance is defined as the distance from tank bottom
surface to the bottom of the tube on the level sensor.
STEP 1: Install O-ring assembly (1).
STEP 2: Mount level sensor with clamp assembly (2) as
shown.
COMPLETED ASSEMBLY
© 2015, by AMETEK, Inc. All rights reserved. Printed in the U.S.A.
Specifications are subject to change without notice. Visit our Web site for the most up-to-date information.
An ISO 9001 Certified Company
"S" style probe with ("R-clip")
NOTE: Extreme temperatures have an effect on level sensor
length. In high temperatures, level sensor length will
expand. In low temperatures, level sensor length will
contract.
MINIMUM TANK BOTTOM CLEARANCES:
"B" style: 1/2", "F" and "S" style: 3/8"