Atlantic Ultraviolet MIN-9 Manual do Proprietário - Página 14
Procurar online ou descarregar pdf Manual do Proprietário para Sistemas de filtragem de água Atlantic Ultraviolet MIN-9. Atlantic Ultraviolet MIN-9 16 páginas. Germicidal ultraviolet water purifiers
Também para Atlantic Ultraviolet MIN-9: Manual do Proprietário (16 páginas), Manual do Proprietário (20 páginas)
TECHNICAL SPECIFICATIONS
Model:
Flow Rate (GPM):
Inlet\Outlet Size:
Number of Lamps:
Lamp Model No.:
Length:
Width:
Height:
Chamber Diameter:
Shipping Weight:
Voltage: j
Power Consumption: k
Max Operating Pressure:
Ambient Temperature:
Quartz Sleeve:
SENTRY
Safety Sensor:
TM
Promate
Audio Alarm:
TM
Promate
Time Delay Mechanism:
TM
Promate
Elapsed Time Indicator, Universal Input:
TM
Promate
Solenoid Valve:
TM
Flow Control Valve:
SureFLO
TM
220v 50Hz, 220v 60Hz, 12v, or 24v DC units are also available. Consult Factory for specific voltage requirements.
j
Total power consumption, including ballast loss (based on 120v unit).
k
All specifications, dimensional data, etc are approximate and subject to change without notice.
OPTIONAL ACCESSORIES
Table 5 – Optional Accessories
Optional Accessories
SENTRY
Safety Sensor
TM
Promate
Time Delay Mechanism
TM
Promate
TM
Elapsed Time Indicator, Universal Input
Promate
Solenoid Valve
TM
SureFLO
TM
Flow Control Valve j
Promate
TM
Audio Alarm
WARNINGS
Many Individuals regard ballasts and units powered by 12v and 24v Direct Current (DC) to be relatively benign from a safety
standpoint. However, a DC ballast, in order to operate an ultraviolet discharge lamp, must produce an output as high as 600v. This
voltage is high enough to produce a very serious or even lethal electric shock. IT IS IMPERATIVE that all DC ballasts and DC
ultraviolet units be wired and grounded appropriately.
Failure to ground all Direct Current (DC) ballasts, and/or the equipment it is employed in,
can result in serious injury or death.
14
Table 4 – Technical Specifications
Available for:
MIN-6 and MIN-9
MIN-6 and MIN-9
MIN-6 and MIN-9
MIN-6 and MIN-9
MIN-6 and MIN-9
MIN-6 and MIN-9
12-Volt and 24-Volt Direct Current (DC) Ballasts and Units
MIN-6
6
3/4" MNPT
1
05-1370-R
22-17/32"
4-1/4"
5-3/8"
4-1/4"
14 lbs.
120v 50/60Hz
21 Watts
100 PSI
35–100°F
1
Optional
Optional
Optional
Optional
Optional
Optional
Optional accessories are available for operation at 120v
60Hz or 230v 50/60Hz. Please specify. Consult Factory
for special input power requirements.
j Unless otherwise specified, PVC flow control valves are supplied.
Stainless Steel Flow Control Valves are available for certain
models. All PVC and Stainless Steel flow control valves are male
NPT. Consult Factory for other flow control valves.
MIN-9
9
3/4" MNPT
1
05-0097A
29-17/32"
4-1/4"
5-3/8"
4-1/4"
18 lbs.
120v 50/60Hz
32 Watts
100 PSI
35–100°F
1
Optional
Optional
Optional
Optional
Optional
Optional