Electrolux WHGL9040CN Manual - Página 39
Procurar online ou descarregar pdf Manual para Campânula de ventilação Electrolux WHGL9040CN. Electrolux WHGL9040CN 40 páginas.
Também para Electrolux WHGL9040CN: Manual de instalação (12 páginas), Manual de instalação (12 páginas), Manual (21 páginas)
Replacing the Charcoal Filter
This filter cannot be washed or regenerated,
and must be replaced when the F touch control
starts to flash, or at least once every 4 months.
The alarm is only triggered when the motor is on.
Enabling/Disabling the alarm signal
• In Recirculation Version Hoods, the Filter sat-
uration Alarm must be enabled at the time of
installation or later.
• Switch off the lights and the motor.
• Disconnect the mains power supply to the
hood by removing the motor unit power supply
cable connector, switching off the power supply
at the Mains or turning the Main switch off.
• Restore the connection, pressing and holding
T2.
• Release the touch control, touch controls L,
T2 and F will light up normally.
• Within 3 seconds press the touch control
F until the key itself flashes to confirm as fol-
lows:
• 2 flashes – Charcoal Filter saturation Alarm
ENABLED
• 1 flash - Charcoal Filter saturation Alarm DIS
ABLED
Reset the alarm signal
• Stop the motor.
• Press the touch control F for at least 4 sec-
onds, until the touch control T1 flashes.
Replace the Filter
• Remove the metal grease filters.
• Remove the saturated charcoal filter, turning
the fasteners provided.
• Fit the new filter and fasten it its correct posi-
tion.
• Put the metal grease filters in their seats.
Light replacement
20 W halogen light.
• Remove the snap-on lamp cover by lev-
ering it from under the metal ring, sup-
porting it with one hand.
• Remove the halogen lamp from the lamp
holder by pulling gently.
• Replace the lamp with a new one of the
same type, making sure that you insert
the two pins properly into the housings
on the lamp holder.
• Replace the snap-on lamp cover.
ENGLISH 39