Power Supply
The Minibel air curtains are supplied with a hose-cable of 1,5 m length (without plug), Ready to be connected
to a connections box. It can be connected to a socket.
Mounting
The air curtain is provided with 8 suspension points: 4 located at the back to be fixed to the wall and 4 on the
top to be fixed to the ceiling (see exact situation in the air curtains characteristics page).
The anchor should be managed according to each unit weight shown on the technical data page. See
available supports on accessories page).
The minimum recommended distance between the inlet grille and any other object is of 80 mm. see the
minimum distances according to the diagram above.
Installation work, electrical wiring and mechanical maintenance must be done by qualified persons
observing these instructions. Each unit should be able to be disconnected according to the applied
norms.
To connect the air curtain there is no need to open the service door. The power supply connector
and all necessary fixations are external.
Electrical heating
The air curtains with electrical heating are protected against overheating. If the internal temperature is over
100ºC, the heating stops.
Storage and transport
¡Attention! Heavy load.
Do not step under hanging load during the transport or assembly.
Store in dry place and protected against the open air in its original packaging. In case the box is open, cover
it against dust. Do not put heavy loads or step on over the packed unit and avoid distortion of casing or other
damages.
Storage temperatures are between -20ºC and +40ºC.
When carrying material, make sure it is not damaged by the forklift (fork penetration in the packaging).
Please observe the packaging instructions.