Absen CR Series Manual do utilizador - Página 14
Procurar online ou descarregar pdf Manual do utilizador para Monitor Absen CR Series. Absen CR Series 19 páginas.
4. Product Cabling
· Preparation before wiring
Before supplying power and signal source to the screen, please check power and data cables connections carefully
and make sure they are wired correctly. Use a multimeter to test the L, N and PE lines in AC power input port and
make sure the tree lines are not short-circuited.
· Power cable connection description
Calculate the maximum power consumption and make sure enough power will be provided. Please consult with your
electrician or power distro manufacturers for specific setup. Input voltage of cabinet is 100-240V/AC. 3X1.5mm2
power supply cable is used to connect the cabinets to the power distros. Maximum 16 cabinets per a 220V circuit,
and 8 cabinets per a 110V circuit..
· Cabinet data ports diagram:
Notes: Single-receiving-card cabinet has two RJ45 as video signal input and output, DATA2 does not need to be
utilized. Double receiving card cabinet have two RJ45 for both DATA1 and DATA2, each with two RJ45 ports used
as signal input and output.
- 13 -
DATA2:RJ45videosignalinput
DATA1:RJ45videosignal
Leading
LED
Applications
CR SeriesUserManual