Using4x4CR1.5setupasanexample,seebelowfordataandpowercablingmethods.
4.1 Power Cabling
16 CR1.5 has a max power consumption of 16 x 0.61 x 0.343 x 520W=1.7kW. Connect the cabinets using the power
jumpers, and use the main power cables to power each circuit.
Note: a main power run will carry a maximum of 16 cabinets per 220V circuit, and 8 cabinets per 110V circuit.