Absen CR1.9 Manual do utilizador - Página 15

Procurar online ou descarregar pdf Manual do utilizador para Monitor Absen CR1.9. Absen CR1.9 19 páginas.

Absen CR1.9 Manual do utilizador
Leading
LED
Applications
Poweroutput
Pilotlamp
Testbutton
Powerinput
Using4x4CR1.5setupasanexample,seebelowfordataandpowercablingmethods.
4.1 Power Cabling
16 CR1.5 has a max power consumption of 16 x 0.61 x 0.343 x 520W=1.7kW. Connect the cabinets using the power
jumpers, and use the main power cables to power each circuit.
Note: a main power run will carry a maximum of 16 cabinets per 220V circuit, and 8 cabinets per 110V circuit.
CR SeriesUserManual
Input100-240V
Powerline
Longpowerline
- 14 -