Absen K5 Manual do utilizador - Página 11

Procurar online ou descarregar pdf Manual do utilizador para Monitor Absen K5. Absen K5 17 páginas.

Absen K5 Manual do utilizador
Leading
LED
Applications

Network cable wiring

The network cable is connected from up to down in "S" shape,or from left to right in "Z" shape. Please
calculate the resolution as per192x192 pixels for each cabinet, and connect signal cables in accordance
with the Signal Sending Card'sl oad range. Please note that the load pixel range for each network interface
is not more than 650,000 pixels.
User Manual
K series

Check for power supply short circuit

After completing the cabinet wiring, please use a multimeter to check if there is any short circuit
at the AC input power supply (L / N / PE) and DC output terminal (VCC / GND). If there is a short
circuit, please carefully investigate the wirings. Make sure all wirings are normal, and only then
connect power to operate the unit.
- 10 -