Drolet ALASKA 2000 Manual de instalação e funcionamento - Página 12
Procurar online ou descarregar pdf Manual de instalação e funcionamento para Fogão Drolet ALASKA 2000. Drolet ALASKA 2000 16 páginas. Oil burning stove
PROBLEMS
ON POSITION 6 (MAXIMUM)
THE FLAME IS LONG AND
SMOKY,
THERE
IS
BUILD UPON THE GLASS
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS
ON POSITION 1 (MINIMUM)
THE FLAME PRODUCES
SMOKE AND SUITS THE
GLASS
TROUBLESHOOTING GUIDE
CAUSES
Position 6 was reached too
quickly.
SUIT
Maximum flow is too high
Cleaning tee and/or burner are
dirty
Orifice of plunger is partially
plugged.
Flow is to low
Page 11 of 15
SOLUTION
1. Set flow regulating handle
to position 1.
2. wait
for
combustion
stabilize.
3. Progressively increase flow
to desired position.
NOTE :
SEE
LIGHTING
PROCEDURES.
1. Set flow to a lower position
2. Call a qualified technician
to adjust the valve.
1. Activate
cleaning
according to procedures
2. Schedule at the next shut
off to clean the burner.
1. Progressively increase flow
to position 6.
2. Push
in
consecutive times on the
thermostatique
regulator
bottom to remove dirt form
the orifice.
NOTE : If the problem persist,
you may have to remove and
clean out the valve with alcohol.
Call
your
specialized
technician.
1. Slightly increase the flow
regulating handle.
2. Call
a
specialized
technician.
to
tee
manual