Drolet DP00071 Manual de operação - Página 13
Procurar online ou descarregar pdf Manual de operação para Fogão Drolet DP00071. Drolet DP00071 16 páginas.
9(17,1* 6<67(0
See the following section for recommandations on
maintaining the venting system.
6.5.9 GASKETS
When maintaining the heat exchanger channel and
the exhaust channel, make sure the gaskets on the
cleaning panels are in good condition. Replace them
if necessary.
Inspect the door gasket. It is important to maintain
the door gasket in good condition. After a while, the
gasket will wear and compress.
If the stove door is not properly sealed, it will be
GLI¿FXOW WR NHHS WKH GRRU JODVV FOHDQ DQG FRPEXVWLRQ
gases may leak into the room.
Adjusting the door may then be required. If the door
DGMXVWPHQW LV QRW VXI¿FLHQW UHSODFH WKH GRRU JDVNHW
with a genuine part.
'225 6($/ 9(5,),&$7,21
Check the door seal by closing and locking the door
on a piece of paper. Check the entire door. Paper
should not slide easily. If the paper slips easily, adjust
the door.
OPERATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST
'225 $'-8670(17
Remove the lock pin by pulling and turning with
pliers. Turn the handle counter clock wise one turn to
increase pressure.
Re-install the lock pin (spring pin) with a small
hammer.
Page 13