11. DIMENSIONS
11.1 GRIP 0,5 LITRE
164 mm
12. HANDLING AND TRANSPORT
Prior to dispatch GRIP lubrication panels are carefully packed in a cardboard carton. During transportation and storage
maintain the equipment the right way up as indicated on the carton.
On receipt, check that the packaging is not damaged and store the equipment in a dry place.
13. PRECAUTIONS IN USE
It is necessary to carefully read the warnings and the risks involved in using the lubrication panel. The operator must
understand the functioning of the unit by studying the user's manual.
Flammability
The oil employed in the lubrication circuit is not normally flammable. It is nonetheless indispensable to take every
precaution against the oil coming into contact with very hot parts or open flames.
Pressure
Prior to any intervention on the equipment ensure that pressure is released from all branches of the lubrication circuit.
Failure to do this could result in oil being discharged under pressure where connections or components are disassembled
(see paragraph 6.6).
Noise
The GRIP lubrication panel does not emit excessive noise, remaining below 70 dB(A).
WARNING: before carrying out the replacement of the mini-pumps, empty the tank
of lubricant.
Characteristic
Pressure at point of connection
Max. quantity of particles in suspension
Max. diameter of particles
Dew point
Max. quantity of oil in suspension
Filler plug
AIR CHARACTERISTICS
114 mm
Requirement
Min. 6 Bar (88.2 psi)
15 mg/Nmc
0.05
2° C (35.6 °F)
5 mg/Nmc
157 mm
(120mm Manual
Version)
8