For the installer

7

About the box

7.1

To unpack the controller

1 Open the box.
2 Separate the accessories.
a
b
a
Installation and operation manual
b
Wood screws + wall plugs (Ø4.0×30)
8

Preparation

8.1

Wiring requirements

All wiring must comply with the following requirements:
Wire specification
Type
Section
Maximum length
9

Installation

NOTICE
During the installation of the controller, keep the installation
environment dust-free in order to avoid any particles
entering the PCB side of the controller.
9.1

Mounting the controller

Before you can mount the controller, you have to determine the
wiring routing, and accordingly, remove a piece of the controller's
rear casing.
The wiring can be routed from the top, the rear, the left, or the
bottom. Remove a piece of the rear casing according to the
illustration:
BRC1H82W+K+S
Madoka wired remote controller
4P596265-1D – 2022.02
Value
Sheathed vinyl cord or cable (2
wires)
2
0.75~1.25 mm
500 m
a
c
a
Wiring from the top
b
Wiring from the left
c
Wiring from the bottom
In case you are routing the wiring from the rear, you do not have to
remove anything.
9.1.1

To mount the controller

1 Take the screws and plugs from the accessory bag.
2 Mount the rear casing to a flat surface.
INFORMATION
If required (e.g. when mounting to a flush-mounted
electrical installation box), mount the rear casing by way of
the knockout holes.
NOTICE
When mounting the rear casing to a flush-mounted
electrical installation box inside a wall, make sure that that
wall is completely flat.
7 About the box
b
Installation and operation manual
9