6. UNPACKING AND INSTALLATION

6.1 UNPACKING
Once the suitable location for installation has been identified, open the packing and remove the equipment. Ensure that no
damage has occurred to the VIP4Tools/Air during transport and storage.
The packing material does not require special disposal precautions as it is in no way dangerous or pollutant.
6.2 INSTALLATION OF THE VIP4Tools/Air PANEL
Provide adequate space for the installation, leaving a minimum perimeter area of 100 mm. Install the VIP4Tools/Air at
"labourer height" in order to prevent abnormal posture or the possibility of impact. Do not install the VIP4Tools/Air in
particularly aggressive or explosive/flammable environments or on parts subject to vibration.
Use only the mounting bracket pre-drilled with 2 holes for Ø 6 mm screws.
6.3 ASSEMBLY OF THE MINI-PUMPS ON THE MIXING BASES (for expansion or replacement)
Assembly of the mini-pumps on the mixing bases takes place using the two fixing screws.
Take care to correctly position the O-ring gaskets between the mini-pump and the mixing base (see the drawing below).
6.4 ASSEMBLY OF THE MIXING UNIT ON THE VIP4TOOLS/AIR (for expansion or replacement)
To insert a new mixing element, proceed as follows:
1. Empty the oil reservoir.
2. Pneumatically disconnect and unscrew the fittings located on the base.
3. Connect the new base, tightening the element with the two screws provided, paying particular
attention to the alignment and the positioning of the gaskets
4. Reposition the fittings on the new base.
6.5 HYDRAULIC CONNECTIONS
The only connection to make is that of the individual pumps fitted with push-in connections at the point to be lubricated. The
piping must be in Ø 4 mm nylon (can be ordered separately from Dropsa).
6.6 PNEUMATIC CONNECTIONS
5