5. COMPONENTS

1
P
Pump
Return
6. UNPACKING AND INSTALLATION
6.1 UNPACKING
Once a suitable installation position has been identified, unpack the product and prepare for installation. It is important to
inspect the product to ensure that there has been no damage during transportation. The packaging material used does not
require any special disposal procedures. You should refer to you regional requirements.
6.2 Installing
1.
Fixing the valve on the pump using four M10 screws supplied, tightening with a torque of 35 Nm. Pay attention at the
correct positioning of ORings.
2.
Connect two outlet pipes to G3 /8" holes marked 1 and 2 on the adapter plate.

7. OPERATING INSTRUCTIONS

7.1 Start-up
Before using the product, a few preliminary checks must be performed:
 Check Modular directional valve integrity;
 Check that the valve is at running temperature and
that the pipes are free of air pockets
Check that the electrical connection has been carried
out correctly;
 Check that there aren't lubricant leakage or air
pressure loss;
 Check that the lock screws are properly screwed up;
4
2
1
Line 2
Line 1
R
35Nm
 Use gloves and safety goggles, as stipulated in the
safety chart for the lubricating oil;
 DO NOT use lubricants that may irritate the NBR
gaskets; if in doubt, contact the Dropsa SpA technical
office, which can provide you with a detailed chart of
recommended oils;
 Not ignore dangers to the health and maintain the
regular hygiene standard.
2
VALVE COMPONENTS
Adapter plate for SUMO/MINISUMO
1
2
Pressure adjustment