A description of each byte in DyNet protocol is the following:
Byte 0: 1C - hexadecimal Logical Message
Byte 1: 01 - Area
Byte 2: 00 – Channel level
Byte 3: 80 - Channel
Byte 4: ff – Channel Offset
Byte 5: 00 – Fade Rate
Byte 6: FF
Byte 7: 1C Checksum
Area - (0 to 255), as set on the Arcpower to give a unique address for each Arcpower unit (i.e. DMX base
address)
Channel Level - (0 to 255), level - 01=100%, FF=0%
Channel - (80 to 83), 80= channel 1, 81= channel 2, 82= channel 3, 83= channel 4, (see Channel Offset
if more than 4 channels)
Channel Offset - (0-255), default (FF)- channel offset in blocks of 4: (FF = CH 1-4, 00 = CH 5-8,
01 = CH 9-12, etc up to 3E = CH 253-256 )
Fade Rate - (0-255), fade rate with 1 second resolution (0= 0 seconds, 255= 255 seconds)
Checksum - (0-255), checksum Byte - used to ensure the integrity of the packet.
Negative two's compliment of the preceding 7 bytes.
Example 1:
0x1C,0x10,0x00,0x80,0xff,0x05,0xff,0x52
This would control channel 1 (i.e. Red) of Arcpower unit, address 16 to a Level of 100% with a fade of 5
seconds.
Example 2:
0x1C,0x05,0xCC,0x82,0xff,0x0A,0xff,0x52
This would control channel 3 (i.e. Blue) of Arcpower unit, address 5 to a level of 20% with a fade of 10
seconds.
(fixed value)
(fixed value)
10