Dryflow 2461IFS Manual do utilizador - Página 4
Procurar online ou descarregar pdf Manual do utilizador para Secador Dryflow 2461IFS. Dryflow 2461IFS 6 páginas.
1
Wiring instructions
Always ensure that the installation
conforms to the current edition of
the I.E.E. wiring regulations, BS 7671
(UK) or the appropriate standards in
your country. Ensure that the unit is
separately fused with a suitably rated
fuse and that it is connected to the
supply with a double pole isolating
switch having a contact separation of
at least 3mm. Care should be taken
that single insulated conductors cannot
come into contact with the mounting
surface.
P.02
4
Intelligent Facility Solutions
WARNING
The hand dryer MUST be isolated from the power
supply during installation or maintenance.
L
N
Please connect the terminal block (see
illustration 1) as follows:
1. Connect the live wire (coloured
red or brown) to the terminal
marked 'L'.
2. Connect the neutral wire (coloured
black or blue) to the terminal
marked 'N'.
3. Connect the earth wire (coloured
green and yellow) to the terminal
marked ' '.