Vertical Blade ASSYs
5. Vertical Blade ASSYs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1. For auto-swing (right and
left) models
1
Release the right and
left shafts.
2
Unfasten the 3 hooks
for each set of vertical
blade ASSY (9 hooks).
3
Pull the vertical blade
ASSYs to the right and
remove them.
6
All manuals and user guides at all-guides.com
Procedure
Vertical blade ASSY
Interlock rod
Hook
Points
Some models have fan
guards. Remove the fan
guards beforehand.
The unit has 3 sets of
vertical blade ASSYs linked
to one another with interlock
rods.
(R21153)
(R2768)
(R6706)
Removal Procedure