Daintree GE Current Lumination Tetra Contour 62189 Series Manual de instalação - Página 2
Procurar online ou descarregar pdf Manual de instalação para Luz exterior Daintree GE Current Lumination Tetra Contour 62189 Series. Daintree GE Current Lumination Tetra Contour 62189 Series 2 páginas. Led luminaire
Lumination
(Tetra
®
LED Driver Installation
1
Mount LED driver and remove
junction box cover. Carefully
remove knockout for AC line
input wires. Install appropriate
electrical fittings in the knockout
holes for wire protection.
Technical Specifications
Input Voltage (VAC)
Input Frequency (Hz)
Input Current (A)
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Enclosure Specification
Dimensions
Note: For remote mounting or loading information refer to the LED System Installation Instructions.
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
Contour)
®
To LED system
To LED system
To LED system
Output wires
Output wires
Output wires
2
Connect the supply wire
that is attached to your LED
system to the red (+) and
black (-) output wires of the
LED driver as outlined in the
"Electrical Connections"
section of your LED system's
Installation Instructions.
Conforms to the following standards:
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
ARCH048 (Rev 04/02/2021)
Green with
Green with
Green with
yellow
yellow
yellow
stripe
stripe
stripe
(ground)
(ground)
(ground)
White (neutral)
White (neutral)
White (neutral)
3
Connect the AC line to the black
(line) and white (neutral) input
wires of the LED driver using
18-14 AWG (0.82-2.08 mm
twist-on wire connectors.
Ground LED driver by connecting
green wire with yellow stripe
to grounding screw. Replace
junction box cover.
Min
Typical
90
100-277
-
50/60
0.7
-
23.25
24.0
-
-
-
-
-40°C
+25°C
0%
-
-40°C
-
IP54: Dry or damp location rated
15.5 in. x 2.5 in. x 1.6 in. (392 mm x 62 mm x 40 mm)
Installation Guide
AC line
AC line
AC line
Black (line)
Black (line)
Black (line)
)
2
Max
305
-
2.5
24.75
3.8
180
+60°C
90%
+85°C