Daintree GE current LightGrid Node Manual de instalação - Página 3

Procurar online ou descarregar pdf Manual de instalação para Sistemas de controlo Daintree GE current LightGrid Node. Daintree GE current LightGrid Node 3 páginas. Outdoor wireless control system

LightGrid Node 2.x Series
Troubleshooting
Symptom
The luminaire is not
turning ON.
I did not see the
dimming sequence in the
first 60 seconds.
Questions
• Leave a Voicemail: 1-877-843-5590
Solution
Check that the pole has power. The relay inside the Controller is Normally Closed, so the
luminaire will always turn ON when the controller is first plugged in.
Unplug the controller, and try plugging it in again. If you still do not see the sequence, check
that the dimming wires of the fixture (Grey & Violet) are properly connected to the dimming
wires of the ANSI socket. If you confirm the wiring is connected and the controller still does
not dim the luminaire, try another new controller.
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
CTRL044 (Rev 05/18/21)