TESTING AND MAINTENANCE
Bell Test
Entering this command will sound the siren and turn ON all the keypad lights for 2 seconds. To perform a
bell test, enter [ ][4] on the keypad.
Weekly Testing
It is recommended that you test your system weekly.
NOTE: Perform system tests in the off-peak hours, such as early morning or late evening.
1 Call to inform your monitoring station that you are testing your system.
2 Disarm the system and ensure that the "Ready" light is ON.
3 Perform a Bell Test by entering [ ][4]. The bell or siren will sound for 2 seconds and all of the lights
on the keypad will come ON. If a trouble condition is indicated after the test, press [ ][2] to view the
trouble condition.
4 Activate each sensor on your system in turn. For example, open protected doors and windows, and
walk in areas protected by motion detectors. Each Zone Light should come ON when each zone is
activated. Each Zone Light will be shut OFF when the zone is restored to normal (when the door or
window is shut, or when motion stops in areas protected by motion detectors).
5 If programmed for operation, press the [P] key. The [P] key may be programmed as silent or audible. If
an alarm sounds, enter an Access Code to silence the alarm.
6 Should the system fail to operate properly, call your alarm dealer for service.
7 When testing is complete, call and advise the monitoring station.
Maintenance
With normal use, your system requires a minimum of maintenance. The following points should be observed:
1 Do not wash the keypad with a wet cloth, and do not use household cleaners, such as glass cleaners,
on the keypad. Light dusting with a cloth slightly dampened with plain water should remove normal
accumulations of dust.
2 The Bell Test is designed to test the condition of the back-up battery installed with your system. Even
with frequent testing, it is recommended that the back-up battery be replaced every three years.
Contact your installing company for information on replacing the battery.
3 For other system devices such as passive infrared, ultrasonic or microwave motion detectors,
glassbreak detectors and other detection devices, consult the manufacturer's literature for testing,
cleaning and maintenance instructions.