DAITEM SH146AX Manual de instalação - Página 12

Procurar online ou descarregar pdf Manual de instalação para Sistema de segurança DAITEM SH146AX. DAITEM SH146AX 18 páginas. External detector antimask

GB

7. Operating options

Dip switches
Infrared sensitivity (depends on the ambient temperature):
an H setting may be advisable in regions where the
climate is mild or hot for most of the year.
H: high sensitivity
H
M: medium sensitivity (factory setting)
M
L: low sensitivity
L
H: high anti-mask sensitivity
HI
STD: standard anti-mask sensitivity
STD
OFF: anti-mask function deactivated (factory setting)
OFF
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Anti-mask (24-hour
protection): when
1 2 3 4 5 6
the detector is
completely masked
ON
for roughly 3
minutes (i.e. an
1 2 3 4 5 6
opaque object is
placed over the
ON
lens), this triggers a
tamper warning.
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
82
Detector in test mode
The LED lights up when something is detected whatever the position
of dip switch 6.
Detector in normal user mode (factory setting)
Normal operating mode
The LED is not lit when dip switch 6 is in OFF position.
Detection every 5 s
Detection every 120 s (factory setting)
Recommended dip switch position to economise on the lithium
battery.
Hostile environment sensitivity
(difficult environment: wind, moving tree leaves or branches, etc.)
The sensitivity will necessarily be lower.
Normal sensitivity (factory setting)
Sensitivity for most installations.
Mandatory position (factory setting)
Mandatory position (factory setting)
Detection LED lighting
(leads to a decrease in detector battery life)
The LED lights up with each detection.
Non-lighting of detection LED (factory setting)
The LED does not light up even when an intruder is detected.
factory setting