DAITEM 155-21X Manual de instalação - Página 11
Procurar online ou descarregar pdf Manual de instalação para Sensores de segurança DAITEM 155-21X. DAITEM 155-21X 20 páginas. Radio heat sensor
6. Manually disabling the detector
It is possible to disable the detector for a 15 min period:
• prior to activities likely to generate abnormal heat (fast rise in
temperature or increase in room temperature above 54°C,
e.g. during DIY work) and hence cause untimely triggering
of the alarm,
• to stop alarm sounding if non-dangerous heat is detected
(e.g. sudden sunshine), (only possible with the detector
having triggered the heat signal and which can be
recognised by its flashing red LED).
In order to disable the detector, press the test button until the
1st beep sounds or until the detector stops its built-in
sounding.
The LED indicating the status of the detector flashes every
2 sec.
Red LeD indicating
detector status
Disabled heat
the LED flashes
detector
other hard-wired
the LED flashes
interconnected heat
every 10 sec.
detectors
Following the 15 min disable period, the detector is
automatically reset to normal operation with the detector
status LED flashing every 10 sec.
iMPoRtAnt: to exit the disable mode before the end of the 15 min period, press the test
button until you hear the built-in sounding (see response description in the testing the
detector section).
White LeD
-
every 2 sec.
-
Sounding
-
-
103
iMPoRtAnt: during the
15 min disable period, the
detector will not detect any
smoke or sound the alarm.
GB