Daitron PFS300A-30 Manual de instruções - Página 7
Procurar online ou descarregar pdf Manual de instruções para Fonte de alimentação Daitron PFS300A-30. Daitron PFS300A-30 7 páginas. Pfs300a series switching power supply
4.Connections
・ Using twisted pairs for I/O and routing them separately from output load wire is ideal to minimize noise interference.
・ For improved noise filtering, add lower value of electrolytic capacitor (Section 2-11, 47µF)
・ Minimize length of output load wiring.
・ Connect FG terminal with earth ground of system using power supply using minimal length possible.
・ Recommended tightening torque for M4 terminal screws is 1.4Nm/1.03lbft
・ To minimize noise interference, be sure to separate the output load line, remote control line, and remote sensing line from
the input line. Noise immunity can be also improved by twisting each line.
・ Attaching a small volume electrolytic capacitor to the load end is also effective to eliminate noise.
・ For safety and noise prevention, ensure a secure grounding connection from ground terminal to equipment enclosure using
appropriate wire size. Otherwise, it may cause electric shock.
・ Recommended tightening torque for M4 I/O terminal screws: 1.4Nm
・ Shut off the power, and carefully make connections for the remote sensing function. Incorrect wiring or poor connection could
cause malfunction.
・ Be sure to use each terminal (pole) of the terminal block at 20A or less.
・ For the loading current of 20A or larger, use two terminal poles at the same time.
5.Troubleshooting
・ Confirm input AC voltage to be within spec of 100-240VAC/50-60Hz.
・ Confirm all input and output connections are in accordance with above.
・ Check the output adjustment potentiometer. Sometimes output OVP function turns off the output power when the potentiometer
is adjusted too high.
・ Please note that an excessive capacitive load can create over current situation.
・ Confirm remote on/off is getting the appropriate voltage for desired operation.
・ Before suspecting a failure.
・ Check if the rated input voltage is connected.
・ Check if the input/output wiring is appropriate.
・ Check if the wire material is not too thin.
・ Check if a large-capacity capacitor is not connected to the load side.
・ Check if the remote control is not active.
・ Check if the accessory connector for CN501 is connected.
The accessory connector is required if the remote sensing function is not used.
・ Check if forced air cooling by external fans is properly functioning.
6.Warranty
The warranty is valid one year from the date of the delivery, except for the following cases.
Repair is provided at a cost for the following cases even during the valid warranty period.
1)
・ Failures or damage caused by misuse or unauthorized repair of the product
・ Failures or damage caused by transport after delivery.
・
Failures or damage caused by a fire, earthquake, wind and water, and other natural disasters, or
abnormal voltage.
・ Failures caused by other devices connected.
For the use in special environments, such as salty, acid, alkaline, dusty, or corrosive environment, please contact us
2)
in advance.
10001-005WE-00