6
SENSITIVITY ADJUSTMENT
It is possible to adjust the detection sensitivit y by adjusting the interruption
When the unit is mounted on a wall, the interruption time can be set longer because the intruder cannot move quickly. This way,
it is possible to prevent an erroneous operation by a bird, small animal,
Adjust the sensitivity with the moving speed of a possible intruder taken into consideration. Al so, be sure to check the unit for
operation after adjustment.
7
OPERATION CHECK
1. Alarm Operation
To check the alarm operation, actually walk along assumed intrusion path near the transmitter
and receiver,
respectively and in-between as shown in the figure below.
Check that the alarm LED lights up and the controller receives the alarm signal when the beam
is interrupted
Transmitter
2. Tamper Operation
Check that the controller receives an abnormal signal when either of the transmitter and
receiver cover is open.
9
TROUBLESHOOTING
Problem
Possible cause
An obstacle exists between transmitter and receiver.
False alarm is output
frequently.
Optical axis alignment is incomplete.
Installation condition is unstable.
Distan
ce be
tween transmitter and receiver exceeds
rated distance.
Beam is interfered with beam from another detector.
There is an electrical noise source in nearby area .
Sunlight enters receiver within
There is a highly reflective wall in parallel with beam.
No ala
rm is o
utput even when
beam is interrupted
Reflectance of floor surface is high.
Beam is interfered with beam from another detector.
Height of installation position is inappropriate.
<Note>
If the trouble remains unsolved even after taking above solution, please consult the dealer of your purchase .
11
DIMENSIONS
77
Knockout
time adjustment volume.
paper and other object that flies in.
INTERRUPTION
TIME
4
1
5
2
3
Receiver
Solution
Remove obstacle.
Perform optical axis alignment again to obtain 1.9V
or more tester level.
Stabilize installation condition.
Change installation position or use other detector with
suitable rated distance.
Take proper measure to avoid beam interference.
Change installation position
±3°
.
angle.
Replace transmitter and receiver.
Adjust optical axis so that it is on the other side of
reflection surface.
Adjust optical axis so that it is on the other side of
reflection surface.
Take proper measure to avoid beam interference.
Change installation position to a proper height .
Mount plate
83
Mount bracket
Center of the
Upper Beam
Center of the
Lower Beam
This unit can be installed
to a pole with 38.0 to
42.7 diameter.
Scale 1
Running
Fast running at full
speed (6.9m/s)
8
OPTICAL AXIS ALIGNMENT
There are two ways for optical axis alignment, by using a level LED and a tester.
1. Using a level LED
Rough adjustment
While looking into the scope located in the center of the
lens 10 to 15 c m away from it, turn the turntable for adju-
stment in the horizontal direction and the vertical adju-
stment
screw for adjustment in the vertical direction until
the detector on the other side is in the center of the scope
as shown in the scope view shown below.
Rough adjustment is OK when level LED turn off.
Turntable
Vertical
adjustment
screw
10
SPECIFICATIONS
Product Name
Model
Power
Current Draw
Operating Temp./Humid.
Storage Temp./Humid.
.
Alarm Output
Max. Coverage
Sensitivity
Lens Movable Range
Installation Site
Weight
Color
12
MAINTENANCE
Be sure to perform periodical inspection at least annually.
Check items
• Tester level: Check that the tester level is 1.9V or more.
• Power input voltage: Check that DC
• Operation: Referring to
Scale 2
Scale 3
Fast walking
Normal walking
Walking with quick
Normal walking
steps (1.2m/s)
(0.7m/s)
2. Using a tester
Fine adjustment
Insert the tester stick into the tester hole in the receiver to check
the tester voltage.
If the measured value is 1.9V or more, adjustment is completed.
If it is less than
1.9V
ment
screw
s of the
transmitter and receiver
voltage is obtained.
1.9V~:good
Scope view
Tester
hole
Photoelectric Detector
NR30TS
NR60TS
DC10.5V
Transmitter : 15mA(at 25℃)
Transmitter : 27mA(at 25℃)
Receiver : 24mA(at 25℃)
Receiver : 24mA(at 25℃)
~
-25℃
+55℃, RH 95%or less
-30℃
~
+60℃, RH 95%or less
Form 1c relay (DC30V, 0.1A) Output Period: min1.0 sec.
Alarm
Form 1b relay (DC30V, 0.1A) Retention time: While cover is opened
Tamper
30m
700m sec. (Selectable)
50 msec.
~
±
Horizontal direction:
Indoor / Outdoor(IP55)
Transmitter: about 380g / Receiver: about 380g
Black Mansel approximation N1.0
.
10.5
V to
28
V is obtained
7
OPERATION CHECK, check alarm operation and tamper operation.
Scale 4~5
Slow moving
Slow action
(0.3~0.5m/s)
adjust the horizontal and vertical adjust-
until 1.9V or more
2.2V~:execellent
NR90TS
~
28V
Transmitter : 38mA(at 25℃)
Receiver : 24mA(at 25℃)
60m
90m
°/ Vertical direction:±5°
90