Atsumi Electric ZSL10 Manual de instruções - Página 3
Procurar online ou descarregar pdf Manual de instruções para Fechaduras Atsumi Electric ZSL10. Atsumi Electric ZSL10 3 páginas. Smart lock
Remote control (0x01)
7
6
5
4
3
Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_SET
Door Lock Mode
Response (0x03)
7
6
5
4
3
Command Class = COMMAND_CLASS_DOOR_LOCK
Command = DOOR_LOCK_OPERATION_REPORT
Door Lock Mode
Outside Door Handles Mode
Inside Door Handles Mode
Door Condition
Lock Timeout Minutes
Lock Timeout Seconds
Target Door Lock Mode
Duration
Indicator (0x87)
When you send this command, it beeps once and the button ashes
blue about 2 second.
7
6
5
4
3
Command Class = COMMAND_CLASS_INDICATOR
Command = INDICATOR_SET
Value
Firmware-Update over the Air (0x7A)
This device is capable of receiving a new rmware 'over the air'.
Target 0 : Z-Wave
Target 1 : INBODY
Target 2 : OUTBODY
Con guration
Con guration Parameters
Parameter No.13
Change the device time setting.
Default : 0
[NOTE]If Default is set to 1, the following items will ignore
the set values and return to the defaults.
Size : 4
Con guration_Set(0x04)
7
6
5
4
3
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter Number
Reserved
Default
Device time(MSB)
...
...
Device time(LSB)
Con gurable time 2000/01/01 00:00:00 ~ 2099/12/31 23:59:59
[NOTE] It cannot be set at any other time.
Con guration_Report(0x06)
The format after the parameter number is the same as SET.
Parameter No.14
Change the lock settings.
Default : 0
[NOTE]If Default is set to 1, the following items will ignore
the set values and return to the defaults.
Size : 2
Con guration_Set(0x04)
7
6
5
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Reserved
Default
Setting the
Volume
hanging
Lock mode
when
Door sensor
unlocking
thumb turn
Con guration_Report(0x06)
The format after the parameter number is the same as SET.
2
1
0
Door Lock Mode
0x00 : Door Unsecured
0xFF : Door Secured
Door Lock Mode
2
1
0
0x00 : Door Unsecured
0xFF : Door Secured
Outside Door Handles Mode
0x00
Inside Door Handles Mode
0x00
Door Condition
0x00
Lock Timeout Minutes
0x00
Lock Timeout Seconds
0x00
Target Door Lock Mode
0x00
Duration
0x00
2
1
0
Value 0xFF
2
1
0
Default
Size
0x38
0x6D
0x43
0x80
4
3
2
1
Parameter Number
Size
Main/sub
O/C
Lock mode
switching for
button
double lock
Moter
0
0
0
torque
Pn14 Setting details
Setting name
Setting the hanging
Volume
Lock mode
O/C button
Main/sub switching
for double lock
Door sensor
Lock mode when unlocking
thumb turn
Motor torque
*1 When locking with OUTBODY, operation with PIN code or
IC card is required.
*2 The lock mode changes to manual (0x02).
*3 The door sensor changes to disable (0x00).
*4 No alarm when the door is forced open.
*5 If the lock mode is manual, it cannot be set to (0x01).
Z-Wave Command Classes
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_ASSOCIATION_V2(On Secure)
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3(On Secure)
COMMAND_CLASS_BASIC_V2(On Secure)
COMMAND_CLASS_BATTERY(On Secure)
COMMAND_CLASS_CONFIGURATION(On Secure)
COMMAND_CLASS_DEVICE_RESET_LOCALLY(On Secure)
COMMAND_CLASS_DOOR_LOCK_V4(On Secure)
COMMAND_CLASS_DOOR_LOCK_LOGGING(On Secure)
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5(On Secure)
COMMAND_CLASS_INDICATOR_V3(On Secure)
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2(On Secure)
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3(On Secure)
COMMAND_CLASS_POWERLEVEL(On Secure)
COMMAND_CLASS_USER̲CODE(On Secure)
COMMAND_CLASS_VERSION̲V3(On Secure)
Speci cations
Product name
Z-Wave Command Classes
Part number
Power supply
Indicating light
Operating temperature
0
Operating humidity
Communication mode
Available frequency
0
Communication distance
Outside dimensions
0
IN - BODY
OUT - BODY
Mass
Value
Detail
0
left hanging door
1
right hanging door
00
mute
01
small
10
medium
11
large
00
automatic locking - short
01
automatic locking - long
10
manual
11
manual *1
0
disable
1
enabled
0
main
1
sub *2,*3
00
disable
01
enabled
10
enabled *4
11
Not used
0
Continuous-unlocking
1
automatic locking *5
0
normal
1
high
Smart Lock
ZSL10
AA type x 4
Red and blue (IN - BODY)
White , red , green (OUT - BODY)
For alkaline batteries
0 to +50 ˚C
For lithium batteries -20 to +50 ˚C
RH 20 to 85% (no condensation)
Z-Wave®
922.5 / 923.9 / 926.3 MHz
About 30 m (prospect)
About 74.8(W) x 129.3(H) x 54.5(D) mm
About 56.9(W) x 93.4(H) x 17.98(D) mm
About 800 g
Default
○
○
○
○
○
○
○
○