DESCrIPTION
ATTACK S – is based on the ATTACK AK type. Disk and stratified pipe
installed in the exchanger enable creation of water layers according to
the temperature. This construction ensures different temperature layers
at the inlets and outlets.
ATTACK SS – is based on the ATTACK AS and the ATTACK S types. It is
accessorized with an extra exchanger for connection to the solar circuit.
ATTACK S: 10× socket G 1 ½", 5× socket G ½"
ATTACK SS: 10× socket G 1 ½", 5× socket G ½", 2× socket G 1" – solar circuit
KEy fOr THE ACCUMULATION TANKS
1 – Flow connection – boiler . . . . . . . . . . . 1 ½"
2 – Freely disposable . . . . . . . . . . . . . . . . 1 ½"
3 – Electrical heating coil (EL) . . . . . . . . . . 1 ½"
4 – Freely disposable . . . . . . . . . . . . . . . . 1 ½"
5 – Return connection – heating circuit . . . . 1 ½"
6 – Flow connection – heating circuit (radiators) 1 ½"
7 – Flow connection – heating circuit (floor) . 1 ½"
8 – Return connection, gas, oil or pellet boiler 1 ½"
TECHNICAL PArAMETErS
S500K
C 1 405 1 013 871
S800K
- 1 545 1 135 946 840 725 315 491 1 340 -
S1000K
- 1 735 1 255 1 036 840 775 295 577 1 495
S1250K
- 1 655 1 175 988 1 000 695 285 565 1 415
S1500K
- 1 755 1 345 1 072 1 050 820 375 653 1 545 -
S2000K
- 1 955 1 408 1 314 1 150 862 315 685 1 682 -
SS500K
C 1 405 1 013 871
SS800K
- 1 545 1 135 946 840 725 315 491 1 340 315 725 790 990 1 842 1 892 1 898 95 105 3
SS1000K - 1 735 1 255 1 036 840 775 295 577 1 495 295 860 790 990 2 031 2 082 2 081 95 121 3
SS1250K - 1 655 1 175 988 1 000 695 285 565 1 415 285 850 950 1 150 1 975 2 025 2 064 95 142 3
SS1500K - 1 755 1 345 1 072 1 050 820 375 653 1 545 375 895 1 000 1 200 2 100 2 150 2 160 95 161 3
SS2000K - 1 955 1 408 1 314 1 150 862 315 685 1 682 315 665 1 100 1 300 2 309 2 356 2 390 95 188 3
Tank
700 621 230 461 1 209 -
700 621 230 461 1 209 230 710 650
9 – Return connection – wood boiler . . . . . 1 ½"
10 – Sensor of solar system or heating . . . . . . ½"
AS – Flow connection of solar system . . . . . . . 1"
RS – Return connection of solar system . . . . . . 1"
SF – Upper solar sensor . . . . . . . . . . . . . . . . ½"
SU – Bottom solar sensor . . . . . . . . . . . . . . . ½"
D1 – Diameter without insulation
D2 – Diameter with insulation
-
650
850 1 680 1 730 1 698 95
-
790 990 1 842 1 892 1 898 95 105 3
-
-
790 990 2 031 2 082 2 081 95 121 3
-
-
950 1 150 1 975 2 025 2 064 95 142 3
- 1 000 1 200 2 100 2 150 2 160 95 161 3
- 1 100 1 300 2 309 2 356 2 390 95 188 3
850 1 680 1 730 1 698 95
ACCUMULATION TANKS
Solar
Tank
exchanger
-
3
-
-
-
488 81
-
-
-
713 157
-
-
-
891 172
-
-
-
1 239 172
-
-
-
1 420 265
-
-
-
1 960 296
-
3
1,8 11,9 10
488 81
2,4 15,9 10
713 157
3
19,8 10
891 172
3
19,8 10 1 239 172
3,6 23,7 10 1 420 265
4,2 27,7 10 1 960 296