DSPPA PAVA9500 Manual - Página 9
Procurar online ou descarregar pdf Manual para Amplificador DSPPA PAVA9500. DSPPA PAVA9500 10 páginas. 8-zone amplifier host with main/backupswitching
"5" for none.
Expansion host:
"1~5" indicates the IDs for device connection. The following devices are connected with the IDs as shown below (that is,
the binary value of the device ID1~5, dialed down for "1", dialed up for "0"). Note: The silk screen printing "1" on the
DIP switch is the highest binary bit, and "5" is the lowest binary bit. For the correspondence between the device
address order and the binary value, please refer to the "Attached Table: Comparison Table of Zone Address and Dialing
Code Settings".
8—SD Card
Used for recording real-time device detection.
Used for storing recording files.
9—Ethernet Connection Port
Mainly used for connecting the software PAVA9000.
Used for remote upgrade of system firmware.
Notes:
1) Device default IP address: 192.168.5.192; communication port number: 10086.
2) If the IP modified by the software PAVA9000 is forgotten, the default IP address can be restored by dialing down the
4th digit mentioned in the item "7" and then dialing up it again.
3) The host PAVA9500 can be directly connected to the PC via this port and automatically identify TIE/EIA-568B and
TIE/EIA-568A standards. In order to unify the interface, it is recommended to use the TIE/EIA-568B standard connection
method.
10—Backup DC24V Power Input Interface
It is an external battery interface and the capacity of the battery is configured according to the actual usage
requirements.
11—CAN Bus Data Dual-Channel Audio Bus Interfaces
With dual RJ45 interfaces, the host can be connected to up to 19 8-zone expansion amplifiers or 30 4-zone
expansion amplifiers hand in hand.
12—CAN-Powered Data Audio Bus Interfaces
With four RJ45 ports, the host can be connected to up to 8 microphones hand in hand.
Connected with a network cable in a star connection mode.
13—MIC1-2 Two Microphone Balanced Input Interfaces
With 5mV input sensitivity and independent volume control.
14—LINE1-2 Two Line Balanced Input Interfaces
With 1000mV input sensitivity and independent volume control.
15—LINE3-4 Two Line Single-Ended Input Interfaces
With 1000mV input sensitivity and independent volume control.
16—LINE OUT Single-Ended Output Interface
With 1000mV input sensitivity and independent volume control.
17—System Fault Output Interface
When the system is faulty, the output interface is disconnected, otherwise it is closed.
/
www.dsppatech.com
1
2
Star Connection Mode
3
4
The specifications will be subject to change without prior notice.
Copyright © Guangzhou DSPPA Audio Co., Ltd. All rights reserved.