AirTools RC-6000 Manual de início rápido
Procurar online ou descarregar pdf Manual de início rápido para Controlo remoto AirTools RC-6000. AirTools RC-6000 2 páginas.
QUICK START GUIDE: RC-6000 Remote Control
Introduction
The AirTools RC-6000 is an accessory remote control
for the 6000 and 6100 Broadcast Audio Delays. The RC-
6000 Remote Control duplicates EXIT, START, COUGH and
DUMP buttons found on the front panel of
Mechanical Data
ITEM
Space Required
Electrical
Ventilation
Weight
FRONT PANEL
ITEM
DESCRIPTION
INACTIVE
Red LED
ACTIVE
Red LED
HALF
Red LED
FULL
Red LED
EXIT
Momentary amber lighted switch
START
Momentary green lighted switch
COUGH
Momentary white lighted switch
DUMP
Momentary red lighted switch
6408 216th Street SW
|
Mountlake Terrace, WA 98043 USA
T
+1.425.778.7728
F
+1.425.778.7727
DESCRIPTION
WDH: 18.16 cm x 9.78 cm x 3.81 cm / 7.15 in x 3.85 in x 1.5 in.
Depth does not include connector allowance.
N/A
Maximum recommended ambient operating temperature is 30
C / 86 F.
0.24 kg / 0.52 lbs.
INACTIVE
EXIT
COUGH
DETAILS
Indicates that the current delay is fully exited (exactly 0.0 seconds) and the status of the delay is
"DELAY REMOVED".
Indicates that some amount of delay is currently built and the delay is currently in some mode of opera-
tion.
Indicates that at least half of the currently set amount of delay has been achieved.
Indicates that the full amount of the currently set amount of delay has been achieved.
Mirrors the status and function of the EXIT button on the front of the delay. The button flashes to
indicate that the delay is "REDUCING DELAY TIME".
Mirrors the status and function of the START button on the front of the delay. The button flashes to
indicate that the delay is "ADDING DELAY TIME".
Mirrors the status and function of the COUGH button on the front of the delay. The button lights while
the button is pressed to indicate that the delay is "WAITING FOR RELEASE".
Mirrors the status and function of the DUMP button on the front of the delay. The button lights while the
button is pressed.
| www.symetrix.co
Introduction and Front Panel
the AirTools 6000 and 6100. It also features LED indiction
of the delay's current status including INACTIVE, ACTIVE,
HALF delay memory built and FULL delay memory built.
DETAILS
Allow at least 1 inch additional clearance for rear panel connec-
tions. Additional depth may be required depending upon your
specific wiring and connections.
Power comes from the 6000 or 6100 via the included cable.
Ventilation should not be impeded by covering the unit with items
such as newspapers, tablecloths, curtains, etc.
RC-6000
ACTIVE
HALF
FULL
START
DUMP
2
REMOTE
CONTROL