Changing Controller IP Address
The DT18 IP address can be changed to any value within the accepted range of
0-255 . 0-255 . 0-255 . 0-250.
In PlaybackPro Plus, select "Network Setup" and then "Setup Controller" on any of
the connected playback systems. Enter the IP you wish to use for the controller and
click "Update". PlaybackPro Plus will then send the new IP to the controller. The
Control buttons will flash 3 times to show the IP address change has occurred. The
IP address of each playback system will need to be changed to the next sequential
IP address as described in Step 1.
Reset Controller to Factory Default IP
The factory default IP address is 192.168.18.160.
If the factory default IP address has changed, on startup all buttons will flash 4 times,
turn off for 5 seconds, then all buttons will illuminate.
Resetting to the factory default IP address requires three steps:
(1) Unplug the DT18 power supply
(2) Press and hold TAKE and END ALL buttons, while plugging in the power supply
(3) All buttons will flash 4 times, then turn off. Release TAKE and END ALL buttons.
All buttons will illuminate within 5 seconds.