Bourgault L7550 Manual de referência rápida

Procurar online ou descarregar pdf Manual de referência rápida para Balanças Bourgault L7550. Bourgault L7550 6 páginas. Weigh scales

www.bourgault.com
1. Weigh Scales Setup
a. When the system is powered up there
should be a Digi-Star UT app loaded
for each Scale Link installed on the rear
axle of the unit (2 UT apps for units
with 2 Scale Links installed).
Digi-Star Scale
Link App
b. After the implement profile for the
specific unit is created and the Apollo
ECU's are detected go to the Imple-
ment/Apollo Seeder/Seeder/Weigh
Scales/ECU tab on the Settings page
Scale Link 1: Tanks 1-4
Scale Link 2: Saddle Tank
i.
Press the Auto Detect and Assign New
ECU's button to detect the Scale Link
ECU's.
ii. For the 9000 A/C there will be a Scale
Link ECU 1 for Tanks 1-4. If equipped
with the Saddle Tank there will be a
Scale Link ECU 2 for Tank 5.
iii. This Auto Detect feature applies
to units that have specific settings
loaded into the respective Scale
Link ECU to detect in the correct
order.
iv. If the weight values are not showing
up for the correct tanks they are
likely detected in the wrong order.
Press the delete button then leave
the page and come back to detect
in the correct order by unplugging
the 6 pin cable on the Scale Link
ECU 2 for the Tank 5, pressing
the Detect New ECU's button and
then plugging the Scale Link ECU
2 back in and pressing the Detect
New ECU's button again.
P/N 0256-80-12
Assy P/N 0256-80-13
Weigh Scales - Quick Reference Guide
c. On the Implement/Apollo Seeder/
Seeder/Weigh Scales/Scales tab you
need to confirm that the Setup and
Calibration numbers are correct for
each channel specific to your model.
Scale Link 1
Scale Link 2
i. These values should already be set
correctly from factory but if you get
an alarm for "Mismatched Setup
or Calibration Numbers" or the
weights don't seem accurate then
these values should be confirmed.
Refer to the Tables on Page 2.
ii. Simply by viewing this Scales tab
on the X35 settings page and then
switching to a different page it will
send these values from the X35 to
the Scale Link ECU.
iii. If you still get this Mismatch
alarm you can set the values on the
Digi-Star UT app for each channel
by pressing the Cycle screen button
twice. Then you can set the appro-
priate values for each channel.
iv. The Affects Scale column for the
9000 A/C should be set to None for
each tank.
Channel
(v. 5.02 revised Jan 2023 )
Cycle Screen
1
Page