ATW AirDew AD-5 Manual do utilizador - Página 10

Procurar online ou descarregar pdf Manual do utilizador para Dispensador de água ATW AirDew AD-5. ATW AirDew AD-5 16 páginas. Atmospheric water system

UV light
1. Power Off and unplug unit. Separate rear cover. (loosen & remove 2
screws with Phillips screwdriver)
2. Remove filters. (See water filter replacement)
3. Disconnect the housing of the U.V from ballast.
4. Remove U.V from U.V clip carefully.
(There may be water in hose, fitting and U.V)
5. Pull to remove U.V while pushing the adaptor of the fitting in
opposite direction.
6. Install a new U.V.
7. After U.V exchange, reset the U.V replacement function by using
Menu/Set button. (see page 13)
Note: DO NOT look at UV ray with naked eyes

Air filter

1. Separate air filter bracket by
loosening 2 easy screws with
hand or Phillips screwdriver.
(Image 5-1)
2. Remove air filter and replace
with new air filter. (Image 5-2)
3. After air filter exchange, reset
the air filter replacement
function by using Menu/Set
button. (see page 13)
Water Generating Capacity
Humid.
50%
Temp.
15
3.2
20
5.2
25
6.6
30
8.4
Daily Water Production in Lab (liters/day)
60%
70%
4.1
5.9
5.8
7.2
8.3
11.7
11.5
16.1
80%
90%
6.4
8.3
8.2
11.3
13.9
17.0
18.2
23.0