D. Troubleshooting
The following information should help you diagnose basic setup or installation
problems.
STATUS
ETHERNET
POWER
PoE
1) POWER LED BLINKS AND OTHER LEDs are OFF: The POWER LED blinks and
other LED lights switch off when PowerGrid 9141s-PoE(s) unit enters power saving
mode. This occurs 30 seconds after the Ethernet connection is lost (see below).
2) ETHERNET LED is OFF: If the Ethernet LED fails to light up, check that the LAN
port of the PowerGrid unit is connected firmly to the LAN port of the other device. To
check the condition of the Ethernet cable, use another cable to test the same
connection.
3)STATUS LED is OFF: Plug both PowerGrid units that you're attempting to pair into
power outlets that are within the same room; both PowerGrid devices should have an
Ethernet cable connected to their respective devices (e.g. PC, Router, Set Top Box,
camera, etc...). After 10 seconds (approx, until all the LEDs of the device blink), the
STATUS LED should light up GREEN. If not, press the "Config" button on each for
2-5 seconds and let go.
4) PoE LED is OFF: If the PoE LED fails to light up, check that the LAN port of the
PowerGrid unit is connected firmly to the LAN port of the PoE device. Also, the PoE
capable device needs to support the 802.3af standard and not other proprietary
standards.
*If you have tried all of the above and are still experiencing problems, you can reset
both devices (PG-9141s & PG-9141s-PoE) to factory default by using a pin to push in
the "Reset" button for 11 seconds (until all the LEDs of the device blink).