Instruction Manual
TH102 TEMPERATURE AND HUMIDITY CONTROLLER
1. Overview
This plug-n-play temperature and humidity controller can be used for
sausage cur ing, green house and incubator applications . The
controller has a two-line LED display, two output sockets, one sensor
modul e and one input power cord. The top dis pl ay s hows the
meas ured temper atur e val ue and bottom dis play show s the
measured humidity value. The left output socket is for heating/cooling
device. Right output socket is for humidifier/dehumidifier. The sensor
module contains both temperature and humidity sensor.
2. Specification
Temperature Control Range -40~80 ° C, -40~176 ° F
0.1 ° C (between -9.9 ~ 80 ° C)
1 ° C (between -40 ~ 10 ° C)
Temperature Resolution
0.1 ° F (between -9.9~99.9 ° F )
1 ° F (between -40 ~ 10 ° F,100 ~176 ° F)
Temperature Accuracy
0.5 ° C
Temperature Control Mode On/Off Control. Heating or Cooling
Temperature Control Output 15A, 120V or 240V AC *
Humidity Control Range
0~99.9% RH
Humidity Resolution
0.1% RH
Humidity Accuracy
3% RH
On/Off Control.
Humidity Control Mode
Humidifying or Dehumidifying
Humidity Control Output
15A, 120V or 240V AC *
Operating Temperature
0~50 ° C
Dimension
91x140x46mm
Input Power
85 ~242VAC, 50Hz/60Hz
Sensor Cable Length
6 ft (2m)
Power Cable Length
3 ft (1m)
* Please note: Although both temperature and humidity output can
handle up to 15A, the combined total power of the two channels are
limited to 1500 Watts due to the limitation of input power cord.
3. Front Panel
Measured
Temperature
Measured
Humidity
Heating/
Cooling Device
On Indicator
Heating/
Cooling
Device Socket
Figure 1. Front Panel
2013.11
INSTRUCTION MANUAL
4. Setup Flow Chart
When the controller is powered on, it will display the measured
temperature and humidity. The controller will keep running according
to the saved setting. If the humidity or temperature sensor is
shorted, the controller will display Err . Please see Figure 2 for the
flow chart to set the parameters.
Set Key
Up Key,Unmute Alarm
Dn Key, Mute Alarm
Alarm Indicator, On
when Alarm Muted
Humidifier/
Dehumidifier
On Indicator
Humidifier/
Dehumidifier
Device Socket
Version 1.3
6 8.9
tSp
T
T
SET
3 6.8
5 4.2
RH
RH
Temperature
SET
Set Point
5 sec
Dn
Edt
Temp
T
Up
Setting
tE
RH
SET
C-F
T
Temperature
F
RH
Unit
SET
tcM
T
Temperature
CL
Control Mode
RH
SET
TdF
Temperature
T
0
Differential
RH
SET
toF
T
Temperature
0
Offset
RH
SET
tAH
T
Temperature
32.0
High Limit Alarm
RH
SET
TAL
Temperature
T
32.0
Low Limit Alarm
RH
SET
tAS
T
Anti-short
0
Cycle Delay
RH
SET
tSF
Temp Sensor
T
Failure Operation
oFF
RH
6 8.9
T
3 6.8
RH
Figure 2. Flow Chart
WWW.AUBERINS.COM
HSp
SET
T
1 5.0
RH
Humidity
Set Point
Edt
T
Humidity
Hu
RH
Setting
SET
HcM
Humidity
T
Control Mode
deH
RH
SET
Hdf
T
Humidity
0
Differential
RH
SET
Hof
T
Humidity
0
RH
Offset
SET
HAh
T
Humidity High
90.0
RH
Limit Alarm
SET
HAL
T
Humidity Low
10.0
RH
Limit Alarm
SET
HAS
Anti-short
T
0
Cycle Delay
RH
SET
HSF
T
Humidity Sensor
off
RH
Failure Operation
SET
P1/3