operation. If the sensor is left outside, the controller will assume the temperature
is low even if the controlled subject is already very hot. The controller will provide
full power to the heater. It will not only overheat the controller, but also damage
your appliance possibly causing a fire. If the sensor is not permanently mounted
on the system and is left outside of the system, this could become a potential
problem, you should enable the open loop alarm function (see page 11 for
details).
This controller is designed to control the devices recommended by Auber
Instruments only. Using it to control a not recommended device can be dangerous
and cause fire. Auber Instruments is not liable for damages caused by misuse of
the controller. If you are not sure the controller can be used, please contact Auber
Instruments before use.
If an abnormal display or noise is observed, turn the controller off, unplug the
power cord and contact the manufacturer before using it again.
Clean the controller only when it is cool and unplugged.
Do not allow children to operate the controller.
Specifications
Input voltage:
Output voltage:
Maximum Current:
Fuse Size:
Control Action:
Control Mode
Output switching device:
Sensor type:
Sensor tip dimensions:
Sensor cable length,
Alarm:
Timer Range:
Temperature resolution:
Temperature display range: -50 to 400 ° C or -58 to 752 ° F
Temperature accuracy:
Dimension:
Weight:
Warranty:
100 to 240 VAC 50 /60 Hz
Same as the input.
15A at 120V, 10A at 240V
15A Fast blow.
Heating (reversed action) or cooling (direct action)
PID, PI, PD, P or On/off
Built-in optically isolated solid state relay with zero voltage
crossing switching.
Pt100 RTD sensor
4 mm diameter x 50 mm long.
3 ft (915 mm)
High limit alarm and Open loop alarm with LED and
buzzer.
1 to 9999 minutes
0.1 ° C or 0.1 ° F
0.1° C or 0.2 ° F for 0-85 ° C (32.0 to 185.0 ° F)
6x3x7 inch (155 x80x180 mm) W x H x D.
2.8 lb (1.3 kg)
1 year for controller and sensor