Auber Instruments AW-HD330 Manual de instruções - Página 4
Procurar online ou descarregar pdf Manual de instruções para Controlador Auber Instruments AW-HD330. Auber Instruments AW-HD330 5 páginas. Dual output programmable humidity controller
AUBER INSTRUMENTS
6 8.9
PV
3 6.8
SV
SET
5 sec
AH
High Limit
PV
20.0
Alarm
SV
SET
AL
Low Limit
PV
20.0
Alarm
SV
SET
Humidity Control
HY
PV
Hysteresis Band
1.0
SV
SET
HYD
Dehumidifier
PV
5.0
Hysteresis Band
SV
SET
HYH
Humidifier
PV
5.0
Hysteresis Band
SV
SET
OFS
PV
Humidity Offset
0
SV
Figure 3. Flow chart of setting up parameters.
6 8.9
PV
3 6.8
SV
SET
H-1
PV
70.0
SV
SET
T-1
PV
2.0
SV
SET
H-2
PV
60.0
SV
SET
T-2
PV
2.0
SV
Figure 4. Flow chart of setting up control program.
A total of 8 steps can be programmed in this controller. Each step contains the
humidity set point (H-X) and time duration (t-X), where "X" is the step number
(e.g. step 4 humidity is represented by H-4, and step 4 time is represented by t-
4). Once time is up, this controller will jump to next step. The time unit can be
set to hour or minute.
To program the humidity profile, briefly press the SET key momentarily. The
top display will show "H-1" and the bottom display will show the humidity set
value for "H-1". Use the ▲ or ▼keys to adjust the bottom display to the
desired value. Then press the SET key again to save the changes and go to
next parameter. Then the top display will show "t-1" and the bottom display will
2022.01
6 8.9
PV
End
3 6.8
SV
SET
App
PSD
PV
Access Code
666
SV
SET
TIM
PV
Time Unit
H
SV
SET
PV
SFA
Sensor Failure
0-0
SV
Operation
SET
A-M
PV
Power Outage/
S
Startup Modes
SV
SET
PRG
PV
Program Modes
ON
SV
SET
SET
PV
AS
Anti-short
Cycle Delay
M 6
SV
68.9
PV
End
36.8
SV
SET
T-8
PV
0
SV
SET
SET
H-8
PV
0
SV
show the preset time for step 1. Use the ▲or ▼keys to adjust the bottom
display to the desired value. Then press SET key again to save the changes
and proceed to next parameter. Repeat operations above until you finish
programming all necessary steps. You can set the time for rest of the steps to
zero so that the controller will skip these steps.
Note: The set value will not be saved unless SET is pressed. The controller will
return to the normal operating mode automatically if it is left alone for 10
seconds.
7. Check the Status
Step Running Time: This indicates how much time has passed since the
beginning of the current step. You can check the Step Running Time while the
controller is in the Program Run Mode by:
1) Short press the STEP key so the display window will show the current step
number "P - X".
2) Wait about 1 second for the step running time to appear in the display
window.
3) Press STEP key again to check the Total Power-on Time (see below) or not
touching any key for 10 seconds so the display window will show the humidity
reading again.
Total Power-on Time: Total Power-on Time shows how much time has
passed since the controller is powered on. You can check the Total Power-on
Time in Program Run, Hold, or Stop Mode:
1) Short press the STEP key twice, you can see "tol" shown in the display
window shortly, and then the Total Power-on Time will be shown.
2) Press STEP again to return to humidity reading.
Once the whole program is finished, the display will show "End" and buzzer will
be ON. Press the start key once to restart the program.
8. Program Jump
This controller allows users to skip parts of the program by jumping to a
specific program step. For example, the controller has run 3 minutes in its 2
step. If the user wants to skip the rest of the 2
then the user can jump to step 4.
To jump to a specified step:
1) Put the controller in either Program Hold or Stop Mode.
2) Press STEP key so the controller will flash "J-X", where "J" indicates this
operation is for jumping to a step ("X" is the step number). Use the UP or
DOWN arrow keys to change step number, then press START key to confirm
and jump. The display window will show JMP ("JUMP") briefly to confirm that
jump is accomplished. Then controller will execute that step, the RUN indicator
will be lit (multi-step mode), and the display window should show humidity
reading as normal.
9. Alarm Buzzer
The controller has a built-in buzzer. Under the following situations, the alarm
buzzer will be triggered:
1) When the humidity alarm is triggered, the buzzer will keep on beeping until
the MUTE key is pressed.
2) When a program step (other than the 8
beep twice.
3) When the entire program is finished (the 8
beeping until the MUTE key is pressed.
When the alarm buzzer is beeping, you can press MUTE key to mute the
alarm.
WWW.AUBERINS.COM
nd
step and the entire 4
step,
nd
th
th
step) is finished, the buzzer will
step), the buzzer will keep on
th
P4/5