3 seconds
0000
Process Time
Set Time
0000
5 seconds
SET
trnG
s
SET
TDIR
dn
SET
tAdj
on
SET
disp
Tot
SET
Tl a
1
SET
Tl b
1
Figure 3. Flow chart of programming
5. 1 How to Set the Timer and Dose Time T1/T2
When timer is not running, in single/double dose display mode,
a) press "SET" key to shift between single dose time T1 and double
dose time T2. When parameter "tAdJ" is programmed to "ON"(see
definition of "tAdJ" in next section), simply press up/ down key will
increase/decrease the set value of each delay time. (hold up/down
key will increase the changing speed exponentially).
b) hold "SET " key for 3s, the display will change to total running time/
cups display mode. For how to program the two different display
modes, please see the definition of "dISP" in next section.
c) hold "SET" key for 5s, the display will enter parameter
programming menu
5.2 Definition of Programming Values:
trnG, Timer range
S:0.01s~99.99s;
M:S:1s~99m59s;
tdir , Timing direction
up:Counting up
dn:Counting down
*note: the timing direction can only be changed in the single and
double dose timer display. The manual control always count up so
that user can use its value to fine tune the single and double dose
setting.
2012.11
0000
Accumulated Value
Total Time
tot
SET
0000
Accumulated Value
Total cups
cups
trnG
S
tdir
dn
tAdj
on
Disp
tot
tL A
1
tL b
1
tAdJ, Time adjust
On: When timer is not running, adjust timer directly by pressing up/
down key from the front panel
Off: Values for timer T1/T2 are locked.
dISP: Display mode
Tot: total time (unit: second).
CUPS: number of cups
*note 1: in Tot mode: total time will only display integer part; when
manual key is pressed and held, the running time is counted into total
time until the manual switch is released
*note 2: in CUPS mode: number of cups will not be counted into total
number when manual key is pressed
*note 3: press down key for 4 seconds will reset the display to zero in
both modes
tL A: constant A
tL b: constant b
These two constants are used for converting the total time display to
other units, such as weight in grams.
dISP= T x A/b
Where, T=T1 or T2. For example, if grinding 1 gram of coffee takes 2
seconds. Set A=1, b=2, will convert the total display unit from second
to gram.
6. Wiring Example
Please see figure 4 on next page for the wiring example.