1.
Power supply indicator (P1-P2)
2.
Alarm indicator (ALM)
3.
Running indicator (RUN)
4.
Lugs
5.
Relay alarm output interface
6.
Grounding screw
7.
CONSOLE port
8.
Power input interface (P1-P2)
9.
Gigabit Bypass M12 interface (Bypass: G1-G2,
G3-G4)
10.
PoE indicator (E1-E16)
11.
100M PoE M12 interface (E1-E16)
12.
Ethernet port indicator (E1-E16, G1-G4)
13.
Gigabit Bypass M12 interface (Bypass: G17-G18,
G19-G20)
14.
PoE indicator (G1-G16)
15.
Gigabit PoE M12 interface (G1-G16)
16.
Ethernet port indicator (G1-G20)
【Mounting Dimension】
Unit: mm
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Wall-mounted Device Mounting】
Step 1.
On the wall of device mounting, place the device on
the wall for reference or refer to the mounting
dimension to mark two screw positions.
Step 2.
Nail screws on the wall and keep 7mm interspace
reserved.
Step 3.
Hang the device on 4 screws and slide downward,
then tighten the screw. Mounting ends.
【Wall-mounted Device Disassembling】
Power off the device.
Unscrew the screw on the wall about 7mm.
Lift the device upward slightly; take out the device,
disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block. Please
pay attention to the above operation sequence.
【Power Supply Connection】
110VDC power supply
The Model I, II, IV and V of this series device
provide two independent DC power supply inputs,
which support reverse connection protection and
power redundancy backup. The power supply interface adopts
M12 A-Coded 4-Pin pin (male) connector. Power supply input
range: 110VDC (66~156VDC). The pin definitions of M12
(male) are shown as follows:
Pin No.
1
2
Pin Definition
V1+
V2+
24VDC power supply
The Model III, VI of this series device provide two independent
DC power supply inputs, which support reverse connection
protection and power redundancy backup. The power supply
interface adopts M12 A-Coded 4-Pin pin (male) connector.
The pin definitions of M12 (male) are shown as follows:
Model III power supply input range: 24VDC (9~36VDC).
Model
VI
power
supply
(18~36VDC).
Pin No.
1
2
Pin Definition
V1+
V2+
【Relay Connection】
Provide 1 M12 D-Coded 4-Pin slot (female) that
supports 1 relay alarm output. R1 and R2 are a set of
normally open contacts of the device alarm relay. They are
open circuit in the state of normal non alarm, closed when any
alarm information occurs. For example, they are closed when
powered off, and send out alarm. The relay supports the
output of DC power supply alarm information or network
abnormality alarm. It can be connected to alarm light or alarm
buzzer or other switching value collecting devices, which can
timely inform operators when the alarm occurs. The pin
definitions of relay are shown as follows:
Pin No.
1
2
Pin Definition
R1
R2
【Console Port Connection】
3
4
V1-
V2-
input
range:
24VDC
3
4
V1-
V2-
3
4
NC
NC